VRF/ VRV Air conditioning system- heat recovery
- Smart climate control with Multi-floor VRF (Variable Refrigerant Flow) air conditioning system
- Heat Pump providing refrigeration to indoor units, including pipework, cabling, condensate, and HVAC Systems installation)
Mechanical Heat recovery ventilation
- Energy-efficient heat recovery ventilation system
- Strip out the plant room equipment to allow PEG-installed services (ventilation solutions)
General ventilation
- Extract ductwork, fire dampers, and grilles.
Fire smoke dampers
- Advanced safety systems installed fire/smoke dampers with a smart control system
Fire suppression System
- Automatic detection and suppression of fires using wet chemical agents engineered explicitly for grease and high-heat applications
- Seamless integration with the canopy extraction system and gas interlock units for complete kitchen safety automation
- System activation shuts off fuel and electricity to affected zones instantly, preventing re-ignition
- Built-in test and maintenance alerts to ensure compliance with fire safety regulations and ongoing system readiness
Air treatment, including carbon filters
- Enhanced air treatment system incorporating multi-stage filtration, including activated carbon filters, to eliminate odours, VOCs, and airborne contaminants.
- Complete installation includes pre-filters, carbon filter housings, access panels for maintenance, and integration into HVAC ductwork, ensuring high indoor air quality and compliance with ventilation performance standards.
SmartVent controls
- Intelligent ventilation control system enabling automated regulation of airflow, temperature, humidity, and air quality across multiple zones
- Installation includes centralised SmartVent control panels, user interfaces, integrated sensors, BMS connectivity, and remote access capability to optimise energy efficiency and ensure responsive indoor climate management.
Mechanical MCC controls
- Installation of 2kW electronic radiators, electrical control, MCC panel controls
Plumbing services and associated controls
- Plumbing installation covering all boiler room requirements and full sanitary provisions
- Supply and installation of equipment for the boiler room: gas boiler, clarifier, pumps, booster set flues, pressurisation unit, controllers, pipework, and lagging
- Commercial plumbing services: installation of soils and wastes
- Supply and installation of cold-water supply (CWS), hot water supply (HWS), hot water return (HWSR), and mains water supply (MWS)
- Grease trap plumbing
- Flushing out and chlorination of storage tanks and lines
Gas services and associated controls
- Comprehensive gas system installation with leak detection
- Gas pipework installation
- Gas panel, gas leak detection, and gas interlock system
UVC Kitchen extract system
- High-efficiency UVC technology integrated into the kitchen extract system, sterilising and removing odours and grease to discharge cleaner, safer air
- Reduces grease build-up inside ductwork, significantly lowering fire risk
- UVC light actively destroys bacteria, viruses, and odours in the exhaust air
- Integrated with stainless steel canopy extract hoods and ducting, reducing the need for frequent manual cleaning and improving fire safety by eliminating grease build-up at the source
- Complete installation includes UVC lamp modules, power supply units, control interface, and safety interlocks, ensuring compliance with hygiene and environmental regulations in commercial kitchens.
Bespoke Kitchen canopies with integrated controls
- Installation of bespoke kitchen canopies equipped with control and automation systems
- Fan speeds automatically adjust based on real-time cooking activity.
- Built-in alert system for operational changes or malfunctions
- Automatic pressure balancing to maintain safe and efficient kitchen airflow
- Custom-designed kitchen extraction system created to control odour and grease, preventing contamination and maintaining air quality standards
Fire suppression System
- Automatic detection and suppression of fires using wet chemical agents engineered explicitly for grease and high-heat applications
- Seamless integration with the canopy extraction system and gas interlock units for complete kitchen safety automation
- System activation shuts off fuel and electricity to affected zones instantly, preventing re-ignition
- Built-in test and maintenance alerts to ensure compliance with fire safety regulations and ongoing system readiness
Dishwasher extract system
- Designed to remove excess steam, heat, and moisture from commercial dishwashing areas
- Integrated moisture sensors trigger extraction based on steam levels to optimise energy use and maintain comfortable working conditions
- Condensation management to prevent water accumulation on surrounding surfaces
Kitchen fresh air system and associated controls
- Ensures clean, filtered air is consistently introduced.
- Maintains correct air pressure to prevent drafts, backflow, and energy loss
- Temperature sensors to monitor air quality and automatically adjust airflow rates for optimal working conditions.
- Real-time monitoring, remote access, and fault alert systems
Refrigeration cold rooms and associated controls
- High-performance refrigeration cold rooms designed for temperature-critical storage, with insulated enclosures, air-tight doors, and integrated thermal barriers
- Complete installation of refrigerant plan, evaporators, control panels, pipework, and monitoring systems, including temperature alarms, defrost cycles, and remote access controls.
Custom Design of all the above systems
- Complete mechanical fit-out solution custom-designed for the project
- Integration of digitalised technology and innovation into mechanical services
- Collaborative design approach to optimise space, efficiency, and user experience.